<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ICECAT-interface SYSTEM "https://data.icecat.biz/dtd/ICECAT-interface_response.dtd">
<!--source: Icecat.biz 2026-->
<!--Language ID: 1-->
<!--Version: v2-->
<ICECAT-interface xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="https://data.icecat.biz/xsd/ICECAT-interface_response.xsd">
 <Product Code="1" HighPic="https://images.icecat.biz/img/norm/high/388665-3210.jpg" HighPicHeight="285" HighPicSize="63495" HighPicWidth="600" ID="388665" LowPic="https://images.icecat.biz/img/norm/low/388665-3210.jpg" LowPicHeight="95" LowPicSize="12523" LowPicWidth="200" Name="Fast Ethernet multimode fiber uplink, (MT)" IntName="Fast Ethernet multimode fiber uplink, (MT)" LocalName="" Pic500x500="https://images.icecat.biz/img/gallery_mediums/img_388665_medium_1480943641_692_26422.jpg" Pic500x500Height="237" Pic500x500Size="90426" Pic500x500Width="500" Prod_id="AT-A40/MT" Quality="ICECAT" ReleaseDate="" ThumbPic="https://images.icecat.biz/thumbs/388665.jpg" ThumbPicSize="3221" Title="Allied Telesis Fast Ethernet multimode fiber uplink, (MT) network media converter 100 Mbit/s 1310 nm" GeneratedIntTitle="Allied Telesis Fast Ethernet multimode fiber uplink, (MT) network media converter" GeneratedLocalTitle="Allied Telesis Fast Ethernet multimode fiber uplink, (MT) network media converter 100 Mbit/s 1310 nm" BrandLocalTitle="">
  <CategoryFeatureGroup ID="33367" No="-8">
   <FeatureGroup ID="0">
    <Name ID="5073" langid="1" Value="Technical details"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1622" No="85">
   <FeatureGroup ID="12">
    <Name ID="4995" langid="1" Value="Ports &amp; interfaces"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1621" No="70">
   <FeatureGroup ID="14">
    <Name ID="5023" langid="1" Value="Weight &amp; dimensions"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1623" No="80">
   <FeatureGroup ID="27">
    <Name ID="5049" langid="1" Value="Power"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1624" No="65">
   <FeatureGroup ID="28">
    <Name ID="5067" langid="1" Value="Operational conditions"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1620" No="100">
   <FeatureGroup ID="35">
    <Name ID="5167" langid="1" Value="Network"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="28049" No="55">
   <FeatureGroup ID="67">
    <Name ID="27423" langid="1" Value="Packaging data"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="41464" No="0">
   <FeatureGroup ID="76">
    <Name ID="28540" langid="1" Value="Certificates"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="6670" No="60">
   <FeatureGroup ID="116">
    <Name ID="78852" langid="1" Value="Packaging content"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="53525" No="0">
   <FeatureGroup ID="143">
    <Name ID="618812" langid="1" Value="Battery"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="6667" No="-100">
   <FeatureGroup ID="146">
    <Name ID="624346" langid="1" Value="Other features"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="11212" No="95">
   <FeatureGroup ID="184">
    <Name ID="1218765" langid="1" Value="Performance"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="70394" No="90">
   <FeatureGroup ID="185">
    <Name ID="1219853" langid="1" Value="Features"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="24987" No="-90">
   <FeatureGroup ID="198">
    <Name ID="1788927" langid="1" Value="Logistics data"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="60017" No="0">
   <FeatureGroup ID="232">
    <Name ID="3464238" langid="1" Value="Supplier features"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="80503" No="75">
   <FeatureGroup ID="279">
    <Name ID="7392238" langid="1" Value="Sustainability"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <Category ID="1008">
   <Name ID="3727733" langid="1" Value="Network Media Converters"/>
  </Category>
  <EANCode/>
  <ReleaseDate/>
  <EndOfLifeDate/>
  <ReasonsToBuy/>
  <BulletPoints/>
  <GeneratedBulletPoints/>
  <ProductBundled/>
  <ProductDescription ID="21866102" LongDesc="&lt;b&gt;Uplink Flexibility&lt;/b&gt;&lt;br&gt;Uplink modules provide a flexible range of&lt;br&gt;interface options, including Gigabit copper, Fast&lt;br&gt;Ethernet fiber, and Gigabit fiber. This flexibility&lt;br&gt;allows Rapier L3 switches to span a wide variety&lt;br&gt;of network topologies and physical media.&lt;br&gt;Uplink modules can be changed or replaced to&lt;br&gt;meet changing network requirements, reducing&lt;br&gt;backup inventory costs." ManualPDFSize="0" ManualPDFURL="" MiddleDesc="" PDFSize="0" PDFURL="" ShortDesc="Fast Ethernet multimode fiber uplink, (MT)" URL="http://www.alliedtelesyn.co.uk/products/detail.aspx?pid=143&amp;lid=39" WarrantyInfo="" langid="1"/>
  <ProductFeature Localized="0" ID="32238026" Local_ID="0" Value="100" CategoryFeature_ID="50552" CategoryFeatureGroup_ID="1620" No="10100150" Optional="0" Presentation_Value="100 Mbit/s" Translated="0" Mandatory="1" Searchable="1">
   <LocalValue Value="100">
    <Measure ID="23">
     <Signs>
      <Sign ID="4" langid="1"><![CDATA[Mbit/s]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1165">
    <Measure ID="23" Sign="">
     <Signs>
      <Sign ID="4" langid="1"><![CDATA[Mbit/s]]></Sign>
     </Signs>
    </Measure>
    <Name ID="3871" langid="1" Value="Maximum data transfer rate"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="32238030" Local_ID="0" Value="100FX" CategoryFeature_ID="10092" CategoryFeatureGroup_ID="1620" No="100004" Optional="1" Presentation_Value="100FX" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="100FX">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="747">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="3025" langid="1" Value="Cabling technology"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="32238033" Local_ID="0" Value="2000" CategoryFeature_ID="50756" CategoryFeatureGroup_ID="11212" No="100150" Optional="0" Presentation_Value="2000 m" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="2000">
    <Measure ID="54">
     <Signs>
      <Sign ID="37" langid="1"><![CDATA[m]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="8555">
    <Measure ID="54" Sign="">
     <Signs>
      <Sign ID="37" langid="1"><![CDATA[m]]></Sign>
     </Signs>
    </Measure>
    <Name ID="720600" langid="1" Value="Maximum transfer distance"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="32238031" Local_ID="0" Value="1310" CategoryFeature_ID="12047" CategoryFeatureGroup_ID="11212" No="100100" Optional="0" Presentation_Value="1310 nm" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="1310">
    <Measure ID="98">
     <Signs>
      <Sign ID="80" langid="1"><![CDATA[nm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="2239">
    <Measure ID="98" Sign="">
     <Signs>
      <Sign ID="80" langid="1"><![CDATA[nm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="11481" langid="1" Value="Wavelength"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="32238029" Local_ID="0" Value="Y" CategoryFeature_ID="26325" CategoryFeatureGroup_ID="70394" No="100070" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="5576">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="91241" langid="1" Value="Hot-swap"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="32238041" Local_ID="0" Value="Y" CategoryFeature_ID="12042" CategoryFeatureGroup_ID="70394" No="100000" Optional="0" Presentation_Value="Yes" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Yes">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1501">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="4699" langid="1" Value="LED indicators"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="32238028" Local_ID="0" Value="Wired" CategoryFeature_ID="12046" CategoryFeatureGroup_ID="1622" No="100050" Optional="0" Presentation_Value="Wired" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Wired">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1655">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="5169" langid="1" Value="Connectivity technology"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="32238036" Local_ID="0" Value="0 - 40" CategoryFeature_ID="12040" CategoryFeatureGroup_ID="1624" No="100040" Optional="0" Presentation_Value="0 - 40 °C" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="0 - 40">
    <Measure ID="65">
     <Signs>
      <Sign ID="48" langid="1"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1112">
    <Measure ID="65" Sign="">
     <Signs>
      <Sign ID="48" langid="1"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
    <Name ID="3765" langid="1" Value="Operating temperature (T-T)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="32238037" Local_ID="0" Value="-25 - 70" CategoryFeature_ID="12041" CategoryFeatureGroup_ID="1624" No="100030" Optional="0" Presentation_Value="-25 - 70 °C" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="-25 - 70">
    <Measure ID="65">
     <Signs>
      <Sign ID="48" langid="1"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="757">
    <Measure ID="65" Sign="">
     <Signs>
      <Sign ID="48" langid="1"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
    <Name ID="3045" langid="1" Value="Storage temperature (T-T)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="32238035" Local_ID="0" Value="5 - 95" CategoryFeature_ID="12039" CategoryFeatureGroup_ID="1624" No="100020" Optional="0" Presentation_Value="5 - 95%" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="5 - 95">
    <Measure ID="64">
     <Signs>
      <Sign ID="47" langid="1"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="703">
    <Measure ID="64" Sign="">
     <Signs>
      <Sign ID="47" langid="1"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
    <Name ID="2937" langid="1" Value="Operating relative humidity (H-H)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="32238038" Local_ID="0" Value="UL, cUL, TUV" CategoryFeature_ID="12048" CategoryFeatureGroup_ID="41464" No="99896" Optional="0" Presentation_Value="UL, cUL, TUV" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="UL, cUL, TUV">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="607">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2745" langid="1" Value="Safety"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="32238039" Local_ID="0" Value="EN55024&#10;UL 60950, CAN/CSA-C22.2&#10;NO. 60950-00, EN60950" CategoryFeature_ID="17792" CategoryFeatureGroup_ID="41464" No="99895" Optional="0" Presentation_Value="EN55024&#10;UL 60950, CAN/CSA-C22.2&#10;NO. 60950-00, EN60950" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="EN55024&#10;UL 60950, CAN/CSA-C22.2&#10;NO. 60950-00, EN60950">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="249">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1865" langid="1" Value="Certification"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="32238027" Local_ID="0" Value="Fast Ethernet" CategoryFeature_ID="10090" CategoryFeatureGroup_ID="6667" No="100001" Optional="1" Presentation_Value="Fast Ethernet" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="Fast Ethernet">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="446">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2259" langid="1" Value="Data link protocols"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="32238034" Local_ID="0" Value="MT-RJ" CategoryFeature_ID="17383" CategoryFeatureGroup_ID="6667" No="100000" Optional="1" Presentation_Value="MT-RJ" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="MT-RJ">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1496">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="4689" langid="1" Value="Connector(s)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="32238040" Local_ID="0" Value="EN55022 class A, FCC class A, VCCI class A" CategoryFeature_ID="12044" CategoryFeatureGroup_ID="6667" No="0" Optional="1" Presentation_Value="EN55022 class A, FCC class A, VCCI class A" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="EN55022 class A, FCC class A, VCCI class A">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="803">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="3137" langid="1" Value="Electromagnetic emissions"/>
   </Feature>
  </ProductFeature>
  <ProductGallery>
   <ProductPicture IsMain="Y" LowPic="https://images.icecat.biz/img/norm/low/388665-3210.jpg" LowPicHeight="95" LowPicWidth="200" LowSize="12523" No="1" Original="https://images.icecat.biz/img/norm/high/388665-3210.jpg" OriginalSize="63495" Pic="https://images.icecat.biz/img/norm/high/388665-3210.jpg" Pic500x500="https://images.icecat.biz/img/gallery_mediums/img_388665_medium_1480943641_692_26422.jpg" Pic500x500Height="237" Pic500x500Size="90426" Pic500x500Width="500" PicHeight="285" PicWidth="600" ProductPicture_ID="13388285" Size="63495" ThumbPic="https://images.icecat.biz/thumbs/388665.jpg" ThumbSize="3221" Type="ProductImage" UpdatedDate="2019-04-04 05:42:21"/>
  </ProductGallery>
  <ProductMultimediaObject>
   <MultimediaObject ContentType="application/pdf" Date="2018-08-10 06:20:07" Description="Generated PDF" KeepAsURL="0" MultimediaObject_ID="0" Type="leaflet" UUID="00000000-0000-0000-0000-000000000000" langid="1" Height="0" PreviewHeight="0" PreviewSize="0" PreviewUrl="" PreviewWidth="0" Size="0" URL="https://icecat.biz/rest/product-pdf?productId=388665&amp;lang=en" Width="0"/>
  </ProductMultimediaObject>
  <ProductRelated ID="2092194" Category_ID="258" Preferred="0">
   <Product ID="23404" Prod_id="AT-RPG6" ThumbPic="" Name="Rapier G6 Layer 3 Switch">
    <Supplier ID="49" Name="Allied Telesis"/>
   </Product>
   <ProductRelatedLocales>
    <ProductRelatedLocale ID="0" langid="0" Preferred="0" StartDate="" EndDate=""/>
   </ProductRelatedLocales>
  </ProductRelated>
  <ProductRelated ID="23418606" Category_ID="1008" Preferred="0">
   <Product ID="388705" Prod_id="AT-A41/SC" ThumbPic="" Name="100FX singlemode fiber uplink, (SC)">
    <Supplier ID="49" Name="Allied Telesis"/>
   </Product>
   <ProductRelatedLocales>
    <ProductRelatedLocale ID="0" langid="0" Preferred="0" StartDate="" EndDate=""/>
   </ProductRelatedLocales>
   <RelationType Code="alternative"/>
  </ProductRelated>
  <SummaryDescription>
   <ShortSummaryDescription langid="1">Allied Telesis Fast Ethernet multimode fiber uplink, (MT), 100 Mbit/s, 100FX, 2000 m, 1310 nm, Wired, 0 - 40 °C</ShortSummaryDescription>
   <LongSummaryDescription langid="1">Allied Telesis Fast Ethernet multimode fiber uplink, (MT). Maximum data transfer rate: 100 Mbit/s, Cabling technology: 100FX. Maximum transfer distance: 2000 m, Wavelength: 1310 nm. Connectivity technology: Wired. Safety: UL, cUL, TUV, Certification: EN55024 UL 60950, CAN/CSA-C22.2 NO. 60950-00, EN60950. Data link protocols: Fast Ethernet, Connector(s): MT-RJ, Electromagnetic emissions: EN55022 class A, FCC class A, VCCI class A</LongSummaryDescription>
  </SummaryDescription>
  <Supplier ID="49" Name="Allied Telesis"/>
  <CatalogObjectCloud>
   <ProductPage QRCodeURL="https://qr.icecat.biz/coc/19a73089-e5ed-4f3c-928e-6c2478b072f0" URL="https://coc.icecat.biz/19a73089-e5ed-4f3c-928e-6c2478b072f0"/>
  </CatalogObjectCloud>
 </Product>
</ICECAT-interface>
